Tandem Mass Tag Labeling Facilitates Reversed-Phase Liquid Chromatography-Mass Spectrometry Analysis of Hydrophilic Phosphopeptides.
Chia-Feng TsaiJeffrey S SmithKrzysztof KrajewskiRui ZhaoAhmed M MoghiebCarrie D NicoraXinyu XiongRonald J MooreTao LiuRichard D SmithJon M JacobsSudarshan RajagopalTujin ShiPublished in: Analytical chemistry (2019)
Protein phosphorylation is a critical post-translational modification (PTM). Despite recent technological advances in reversed-phase liquid chromatography (RPLC)-mass spectrometry (MS)-based proteomics, comprehensive phosphoproteomic coverage in complex biological systems remains challenging, especially for hydrophilic phosphopeptides with enriched regions of serines, threonines, and tyrosines that often orchestrate critical biological functions. To address this issue, we developed a simple, easily implemented method to introduce a commonly used tandem mass tag (TMT) to increase peptide hydrophobicity, effectively enhancing RPLC-MS analysis of hydrophilic peptides. Different from conventional TMT labeling, this method capitalizes on using a nonprimary amine buffer and TMT labeling occurring before C18-based solid phase extraction. Through phosphoproteomic analyses of MCF7 cells, we have demonstrated that this method can greatly increase the number of identified hydrophilic phosphopeptides and improve MS detection signals. We applied this method to study the peptide QPSSSR, a very hydrophilic tryptic peptide located on the C-terminus of the G protein-coupled receptor (GPCR) CXCR3. Identification of QPSSSR has never been reported, and we were unable to detect it by traditional methods. We validated our TMT labeling strategy by comparative RPLC-MS analyses of both a hydrophilic QPSSSR peptide library as well as common phosphopeptides. We further confirmed the utility of this method by quantifying QPSSSR phosphorylation abundances in HEK 293 cells under different treatment conditions predicted to alter QPSSSR phosphorylation. We anticipate that this simple TMT labeling method can be broadly used not only for decoding GPCR phosphoproteome but also for effective RPLC-MS analysis of other highly hydrophilic analytes.
Keyphrases
- liquid chromatography
- mass spectrometry
- high resolution mass spectrometry
- solid phase extraction
- tandem mass spectrometry
- high performance liquid chromatography
- gas chromatography
- simultaneous determination
- ultra high performance liquid chromatography
- capillary electrophoresis
- high resolution
- induced apoptosis
- liquid chromatography tandem mass spectrometry
- molecularly imprinted
- ms ms
- cell cycle arrest
- small molecule
- cell death
- gas chromatography mass spectrometry
- endoplasmic reticulum stress
- protein kinase
- amino acid
- breast cancer cells
- smoking cessation