Login / Signup

Update on PI-RADS Version 2.1 Diagnostic Performance Benchmarks for Prostate MRI: Systematic Review and Meta-Analysis.

Benedict OertherAndrea NedelcuHannes EngelChristine M SchmuckerGuido SchwarzerTimo S BruggerIvo G SchootsMichel EisenblätterAugust SigleChristian GratzkeFabian BambergMatthias Benndorf
Published in: Radiology (2024)
Background Prostate MRI for the detection of clinically significant prostate cancer (csPCa) is standardized by the Prostate Imaging Reporting and Data System (PI-RADS), currently in version 2.1. A systematic review and meta-analysis infrastructure with a 12-month update cycle was established to evaluate the diagnostic performance of PI-RADS over time. Purpose To provide estimates of diagnostic accuracy and cancer detection rates (CDRs) of PI-RADS version 2.1 categories for prostate MRI, which is required for further evidence-based patient management. Materials and Methods A systematic search of PubMed, Embase, Cochrane Library, and multiple trial registers (English-language studies published from March 1, 2019, to August 30, 2022) was performed. Studies that reported data on diagnostic accuracy or CDRs of PI-RADS version 2.1 with csPCa as the primary outcome were included. For the meta-analysis, pooled estimates for sensitivity, specificity, and CDRs were derived from extracted data at the lesion level and patient level. Sensitivity and specificity for PI-RADS greater than or equal to 3 and PI-RADS greater than or equal to 4 considered as test positive were investigated. In addition to individual PI-RADS categories 1-5, subgroup analyses of subcategories (ie, 2+1, 3+0) were performed. Results A total of 70 studies (11 686 lesions, 13 330 patients) were included. At the patient level, with PI-RADS greater than or equal to 3 considered positive, meta-analysis found a 96% summary sensitivity (95% CI: 95, 98) and 43% specificity (95% CI: 33, 54), with an area under the summary receiver operating characteristic (SROC) curve of 0.86 (95% CI: 0.75, 0.93). For PI-RADS greater than or equal to 4, meta-analysis found an 89% sensitivity (95% CI: 85, 92) and 66% specificity (95% CI: 58, 74), with an area under the SROC curve of 0.89 (95% CI: 0.85, 0.92). CDRs were as follows: PI-RADS 1, 6%; PI-RADS 2, 5%; PI-RADS 3, 19%; PI-RADS 4, 54%; and PI-RADS 5, 84%. The CDR was 12% (95% CI: 7, 19) for transition zone 2+1 lesions and 19% (95% CI: 12, 29) for 3+0 lesions ( P = .12). Conclusion Estimates of diagnostic accuracy and CDRs for PI-RADS version 2.1 categories are provided for quality benchmarking and to guide further evidence-based patient management. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Tammisetti and Jacobs in this issue.
Keyphrases