The Importance of a Distance between the Lines Encircling Pulmonary Veins in Atrial Fibrillation Ablation on First-Pass Isolation Ratio and Clinical Outcomes.
Krystian KrzyżanowskiMarek KiliszekBeata Uziębło-ŻyczkowskaMagdalena Smalc-StasiakAleksandra WinklerPaweł KrzesińkiPublished in: International journal of environmental research and public health (2023)
The distance between the ablation lines did not influence the rate of first-pass isolation and arrhythmia recurrence in the long-term follow-up after PVI procedures incorporating the ablation index protocol.