Inter-Individual Variations: A Challenge for the Standardisation of Complement Activation Assays.

Dorelia LipsaAna Ruiz MorenoCloé DesmetIvana BianchiOtmar GeissPascal ColpoSusanne Bremer-Hoffmann
Published in: International journal of nanomedicine (2023)
Our studies demonstrate that the use of pooled serum can lead to an over- or under-estimation of immunological response in particular for individuals with pre-existing pathologies. This is of high relevance when developing medical products based on nanomaterials and asks for a review of the current practice to use PS from healthy donors for the prediction of immunological effects of drugs in patients. A better understanding of individual toxicological responses to xenobiotics should be an essential part in safety assessments.