The Combined Effect of Static Stretching and Foam Rolling With or Without Vibration on the Range of Motion, Muscle Performance, and Tissue Hardness of the Knee Extensor.
Masatoshi NakamuraAndreas KonradKazuki KasaharaRiku YoshidaYuta MurakamiShigeru SatoKodai AizawaRyoma KoizumiJan WilkePublished in: Journal of strength and conditioning research (2022)
Nakamura, M, Konrad, A, Kasahara, K, Yoshida, R, Murakami, Y, Sato, S, Aizawa, K, Koizumi, R, and Wilke, J. The combined effect of static stretching and foam rolling with or without vibration on the range of motion, muscle performance, and tissue hardness of the knee extensor. J Strength Cond Res XX(X): 000-000, 2022-Although the combination of static stretching (SS) and foam rolling (FR) is frequently used for warm-up in sports, the effect of the intervention order is unclear. This study compared mechanical tissue properties, pain sensitivity, and motor function after SS and FR (with and without vibration) performed in different orders. Our randomized, controlled, crossover experiment included 15 healthy male subjects (22.5 ± 3.3 years) who visited the laboratory 5 times (inactive control condition, FR + SS, FRvibration + SS, SS + FR, and SS + FRvibration) with an interval of ≥48 hours. In each session, subjects completed three 60-second bouts of FR and SS, targeting the anterior thigh. Pressure pain threshold, tissue hardness, knee flexion range of motion (ROM), maximal voluntary isometric (MVC-ISO), and concentric (MVC-CON) torque, as well as countermovement jump height, were determined before and after the intervention. All interventions significantly (p < 0.01) increased knee flexion ROM (d = 0.78, d = 0.87, d = 1.39, and d = 0.87, respectively) while decreasing tissue hardness (d = -1.25, d = -1.09, d = -1.18, and d = -1.24, respectively). However, MVC-ISO torque was significantly reduced only after FR + SS (p = 0.05, d = -0.59). Our results suggest that SS should be followed by FR when aiming to increase ROM and reduce tissue hardness without concomitant stretch-induced force deficits (MVC-ISO, MVC-CON, and countermovement jump height). Additionally, adding vibration to FR does not seem to affect the magnitude of changes observed in the examined outcomes.
Keyphrases
- total knee arthroplasty
- randomized controlled trial
- knee osteoarthritis
- body mass index
- skeletal muscle
- double blind
- type diabetes
- clinical trial
- traumatic brain injury
- open label
- blood pressure
- spinal cord injury
- neuropathic pain
- placebo controlled
- oxidative stress
- insulin resistance
- high resolution
- drug delivery
- resistance training
- heart rate
- high speed
- phase ii
- diabetic rats