Login / Signup

Estimation of maximum sprinting speed with timing gates: greater accuracy of 5-m split times compared to 10-m splits.

Santiago ZabaloyTomás T FreitasJorge Carlos-VivasJulián C GiráldezIrineu LoturcoFernando Pareja-BlancoJavier Gálvez GonzálezPedro Emilio Alcaraz-Ramón
Published in: Sports biomechanics (2021)
This study assessed the validity of 5-m (TG5) and 10-m (TG10) split times measured with timing gates to estimate maximum sprint speed (MSS) against a criterion measure radar gun (RG) during the maximum velocity phase of a 30-m sprint. Nineteen amateur rugby players performed two 30-m sprints. The timing gates were placed at the starting line and at 5-, 10-, 20-, 25- and 30-m. In addition, a RG was used to measure instantaneous velocity. Both trials per participant were used selected as references. MSS obtained from TG10, TG5 and RG showed high intraclass correlation coefficients (0.971-0.978), low coefficients of variation (1.14-1.70%) and smallest detectable changes (<0.02 m/s). Pairwise comparison revealed differences (p = 0.002) in MSS when comparing TG10 to RG, but not TG5 and RG (p = 0.957). Almost perfect correlations were found between RG, TG5 and TG10 (r > 0.926, p < 0.001). In conclusion, MSS obtained from TG5, TG10 and RG presented good intra-session reliability. However, practitioners should be aware that substantial differences exist between TG10 and RG. For the assessment of MSS in team-sport athletes, it is recommended the use of TG5 for more accurate estimations when a gold standard criterion is not available.
Keyphrases
  • mass spectrometry
  • primary care
  • high intensity
  • single cell