Diastolic delta best predicts paravalvular regurgitation after transcatheter aortic valve replacement as assessed by cardiac magnetic resonance: the APPOSE trial.
Maxim J P RooijakkersNiels A StensMarleen H van WelyKees van der WulpLaura RodwellHelmut GehlmannLeen A F M van GarsseGuillaume S C GeuzebroekMichel W A VerkroostJesse HabetsSaloua El MessaoudiDick H J ThijssenRobin NijveldtNiels van RoyenPublished in: European heart journal. Cardiovascular Imaging (2023)
DD measured during TAVR best predicts relevant PVR. Correction for heart rate (HR-DD) or systolic blood pressure (ARI, ARI ratio) did not improve this predictive value.