Quantitative MRI volumetry, diffusivity, cerebrovascular flow, and cranial hydrodynamics during head-down tilt and hypercapnia: the SPACECOT study.
Larry A KramerKhader M HasanAshot E SargsyanKarina Marshall-GoebelJörn RittwegerDorit DonovielSaki HigashiBenson MwangiDarius A GerlachEric M Bershadnull nullPublished in: Journal of applied physiology (Bethesda, Md. : 1985) (2017)
To improve the pathophysiological understanding of visual changes observed in astronauts, we aimed to use quantitative MRI to measure anatomic and physiological responses during a ground-based spaceflight analog (head-down tilt, HDT) combined with increased ambient carbon dioxide (CO2). Six healthy, male subjects participated in the double-blinded, randomized crossover design study with two conditions: 26.5 h of -12° HDT with ambient air and with 0.5% CO2, both followed by 2.5-h exposure to 3% CO2 Volume and mean diffusivity quantification of the lateral ventricle and phase-contrast flow sequences of the internal carotid arteries and cerebral aqueduct were acquired at 3 T. Compared with supine baseline, HDT (ambient air) resulted in an increase in lateral ventricular volume (P = 0.03). Cerebral blood flow, however, decreased with HDT in the presence of either ambient air or 0.5% CO2 (P = 0.002 and P = 0.01, respectively); this was partially reversed by acute 3% CO2 exposure. Following HDT (ambient air), exposure to 3% CO2 increased aqueductal cerebral spinal fluid velocity amplitude (P = 0.01) and lateral ventricle cerebrospinal fluid (CSF) mean diffusivity (P = 0.001). We concluded that HDT causes alterations in cranial anatomy and physiology that are associated with decreased craniospinal compliance. Brief exposure to 3% CO2 augments CSF pulsatility within the cerebral aqueduct and lateral ventricles.NEW & NOTEWORTHY Head-down tilt causes increased lateral ventricular volume and decreased cerebrovascular flow after 26.5 h. Additional short exposure to 3% ambient carbon dioxide levels causes increased cerebrovascular flow associated with increased cerebrospinal fluid pulsatility at the cerebral aqueduct. Head-down tilt with chronically elevated 0.5% ambient carbon dioxide and acutely elevated 3% ambient carbon dioxide causes increased mean diffusivity of cerebral spinal fluid within the lateral ventricles.
Keyphrases
- carbon dioxide
- air pollution
- particulate matter
- cerebrospinal fluid
- cerebral blood flow
- subarachnoid hemorrhage
- minimally invasive
- magnetic resonance imaging
- heart failure
- contrast enhanced
- computed tomography
- double blind
- high resolution
- magnetic resonance
- pulmonary hypertension
- randomized controlled trial
- pulmonary artery
- cerebral ischemia
- brain injury
- intensive care unit
- catheter ablation
- clinical trial
- study protocol
- atrial fibrillation
- optical coherence tomography
- drug induced