Comparison of the diagnostic accuracy of 18F-Fluorocholine PET and 11C-Methionine PET for parathyroid localization in primary hyperparathyroidism: a systematic review and meta-analysis.
Fabio BiolettoMarco BaraleMirko Parasiliti-CaprinoNunzia PrencipeAlessandro Maria BertonMassimo ProcopioDésirée DeandreisEzio GhigoPublished in: European journal of endocrinology (2021)
This was the first meta-analysis that specifically compared the diagnostic accuracy of 11C-Methionine and 18F-Fluorocholine PET for parathyroid localization in patients with primary hyperparathyroidism. Our results suggested a superior performance of 18F-Fluorocholine in terms of sensitivity, while the two tracers had comparable accuracy in terms of positive predictive value.