Login / Signup

Functional outcome and quality of life following resection of the proximal humerus performed for musculoskeletal tumors and reconstruction done by four different methods.

I AntalG SzőkeM SzendrőiK SzalayT PerlakyJ KissG Skaliczki
Published in: Musculoskeletal surgery (2023)
Based on the results of our study the best functional performance (range of motion and patient compliance) was achieved in the a reverse prosthesis-allograft combination group-in cases where the axillary nerve could be spared. The use of an osteoarticular allograft resulted in unsatisfying functional results and high complication rates, therefore we do not recommend it as a reconstructive method following resection of the proximal humerus due to either primary or metastatic bone tumors. Young patients who have good life expectancy but a small humerus or intramedullar cavity reconstruction by implantation of a fibula autograft is a good option. For patients with a poor prognosis (i.g. bone metastases) or in cases where the axillary nerve must be sacrificed, hemiarthroplasty using a tumor endoprosthesis was found to have acceptable results with a low complication rate. According to the MSTS and SF-36 functional scoring systems patients compliance was nearly identical following all four types of reconstruction techniques; the underlying cause may be the complexity of the shoulder girdle. However, we recommend the implantation of a reverse shoulder prosthesis-allograft whenever indication is appropriate, as it has been demonstrated to provide excellent functional outcomes, especially in young adults.
Keyphrases