Login / Signup

Efficacy and safety of a dual-scan protocol for carbon dioxide laser in the treatment of split-thickness skin graft contraction in a red Duroc pig model.

Jie LiSally Kiu-Huen NgWenjing XiZheng ZhangXiaodian WangHua LiWeijie SuJingyan WangYixin Zhang
Published in: Burns & trauma (2021)
Dual-scan protocol could achieve superficial ablation and deep release of contracted split-thickness skin graft in a single treatment, with similar contraction release and texture improvement compared to a single deep scan. Its main advantage is to restore a smoother scar appearance. Adequate laser penetration was necessary for the release of contracted scars.