Mechanical Vertebral Body Augmentation Versus Conventional Balloon Kyphoplasty for Osteoporotic Thoracolumbar Compression Fractures: A Systematic Review and Meta-Analysis of Outcomes.
Matthew MacciaccheraJake Michael McDonnellAisyah AmirAubrie SowaGráinne CunniffeStacey DarwishCiara MurphyJoseph S ButlerPublished in: Global spine journal (2024)
The results of this meta-analysis highlight no significant improvement in clinical or radiological outcomes for MPVA systems when compared to balloon kyphoplasty for vertebral body augmentation. Further research is needed to establish a true benefit over traditional operative methods.