Intraocular Lens Power Calculation Formulas in Children-A Systematic Review.
Wiktor StopyraAndrzej E GrzybowskiPublished in: Journal of clinical medicine (2024)
Objectives: The selection of an appropriate formula for intraocular lens power calculation is crucial in phacoemulsification, particularly in pediatric patients. The most commonly used formulas are described and their accuracy evaluated in this study. Methods: This review includes papers evaluating the accuracy of intraocular lens power calculation formulas for children's eyes published from 2019-2024. The articles were identified by a literature search of medical and other databases (Pubmed/MEDLINE, Crossref, Google Scholar) using the combination of the following key words: "IOL power calculation formula", "pediatric cataract", "congenital cataract", "pediatric intraocular lens implantation", "lens power estimation", "IOL power selection", "phacoemulsification", "Hoffer Q", "Holladay 1", "SRK/T", "Barrett Universal II", "Hill-RBF", and "Kane". A total of 14 of the most recent peer-reviewed papers in English with the maximum sample sizes and the greatest number of compared formulas were considered. Results: The outcomes of mean absolute error and percentage of predictions within ±0.5 D and ±1.0 D were used to assess the accuracy of the formulas. In terms of MAE, Hoffer Q yielded the best result most often, just ahead of SRK/T and Barrett Universal II, which, together with Holladay 1, most often yielded the second-best outcomes. Considering patients with PE within ±1.0 D, Barrett Universal II most often gave the best results and Holladay 1 most often gave the second-best. Conclusions: Barrett Universal II seems to be the most accurate formula for intraocular lens calculation for children's eyes. Very good postoperative outcomes can also be achieved using the Holladay 1 formula. However, there is still no agreement in terms of formula choice.