Incongruous effect of phenylephrine on changes in cerebral blood volume measured by near-infrared spectroscopy (NIRS) indicating extracranial contamination.
Anneliese T MoermanMichael VandenheuvelPieter-Jan TuybensCarla Van GompelStefan G De HertPublished in: Journal of clinical monitoring and computing (2021)
We assessed extracranial contamination of the near-infrared spectroscopy (NIRS) signal during administration of phenylephrine. The study was performed with NIRO 200NX which employs both the Modified Beer-Lambert (MBL) method to measure total hemoglobin (tHb, expressed in µM), and Spatially Resolved Spectroscopy (SRS) to measure total hemoglobin content (nTHI, expressed in arbitrary units (a.u.)). SRS tends to not be affected by extracranial blood flow. As vasoconstriction with phenylephrine mainly occurs in the extracranial area, we hypothesized that if NIRS measurements are indeed prone to extracranial contamination, tHb will be more affected by the administration of phenylephrine than nTHI. After ethical committee approval, 20 consenting cardiac surgery patients were included. Phenylephrine was administered whenever clinically indicated and its effect on nTHI and tHb was evaluated. To adjust for the difference in raw scale units, Z-scores were calculated. Data were analyzed with Wilcoxon Signed Ranks Test and the Hodges-Lehmann method. A total of 191 data sets were obtained in 20 patients (10 male, 65 ± 15 years, 77 ± 16 kg, 166 ± 11 cm). The median difference before and after administration of phenylephrine was - 0.006 a.u. [95%CI - 0.010 to - 0.002] (p < 0.001) and - 0.415 µM [95%CI - 0.665 to - 0.205] (p < 0.001) for nTHI and tHb, respectively. The median difference between the Z-scores of nTHI and tHb was - 0.02 [95%CI - 0.04 to - 0.003] (p = 0.03), with a higher variability in the Z-scores of tHb. Phenylephrine induced significant larger changes in MBL values compared to SRS values, indicating that the MBL method might be more prone to extracranial contamination. Trial and clinical registry: Trial registration number: B670201939459, ethical committee number: 2019/0265, date of approval: March 19, 2019.
Keyphrases
- internal carotid artery
- end stage renal disease
- risk assessment
- blood flow
- cardiac surgery
- newly diagnosed
- chronic kidney disease
- drinking water
- ejection fraction
- clinical trial
- health risk
- study protocol
- electronic health record
- randomized controlled trial
- peritoneal dialysis
- middle cerebral artery
- big data
- patient reported outcomes
- phase ii
- climate change
- brain injury
- heavy metals
- endothelial cells
- open label
- solid state