Analytical validation of a flow cytometric protocol for quantification of platelet microparticles in dogs.
Signe E CremerAnne K H KroghMatilda E K HedströmLiselotte B ChristiansenInge TarnowAnnemarie T KristensenPublished in: Veterinary clinical pathology (2018)
Calcium induced higher in vitro PMP concentrations, likely due to platelet activation. PMP concentrations were reliably quantified in WB, indicating the potential for clinical applications. PPP analyses were unreliable due to high inter-CV and DL overlap, and not obtainable due to hemolysis and lipemia interference.