Prehospital invasive arterial blood pressure monitoring in critically ill patients attended by a UK helicopter emergency medical service- a retrospective observational review of practice.
Emma D ButterfieldJames PriceMarco BonsanoKate LachowyczZachary StarrChristopher T EdmundsJon BarrattRob MajorP S C ReesEd Benjamin Graham BarnardPublished in: Scandinavian journal of trauma, resuscitation and emergency medicine (2024)
This study describes over 1000 cases of prehospital arterial catheterisation and IABP monitoring in a UK HEMS system and has demonstrated feasibility at scale. The high-fidelity of invasive arterial blood pressure monitoring with the additional benefit of arterial blood gas analysis presents an attractive translation of in-hospital critical care to the prehospital setting.