Improved matrix purification using a graphene oxide-coated melamine sponge for UPLC-MS/MS-based determination of 37 veterinary drugs in milks.
Xu XuJia LvJintian ZhouBaocheng JiLanrui YangGaigai XuZhuchen HouLulu LiYan-Hong BaiPublished in: Analytical methods : advancing methods and applications (2024)
A rapid and highly sensitive method was established for the analysis of 37 veterinary drug residues in milk using a modified QuEChERS method based on a reduced graphene oxide-coated melamine sponge (rGO@MeS) coupled with UPLC-MS/MS. Under optimal chromatographic and mass spectrometric conditions, the effects of different dehydrated salts (MgSO 4 and Na 2 SO 4 ) and metal chelating agents (Na 2 EDTA) on extraction efficiency were first investigated. Next, the influence of a dynamic and static purification mode was evaluated in terms of drug recoveries. Calibration curves of 37 veterinary drugs were constructed in the range 0.6-500 μg kg -1 , and good linearities were obtained with all determination coefficients ( R 2 ) ≥0.992. The limits of detection (LODs) and quantitation (LOQs) were in the range 0.3-1.1 μg kg -1 and 0.6-3.5 μg kg -1 , respectively. The recoveries of all compounds were in the range 61.3-118.2% at three spiked levels (20, 100, and 200 μg kg -1 ) with RSDs ≤15.4% for both intra- and inter-day precisions. Compared to pristine melamine sponges and commercial adsorbents (C18, PSA, and GCB), rGO@MeS demonstrated an equal or even better purification performance in terms of recoveries, matrix effects, and matrix removal efficiency. This method is rapid, simple, efficient, and appropriate for the qualitative and quantitative analyses of 37 veterinary drug residues in milk, providing a new detection strategy and technical support for the routine analysis of animal-derived food.
Keyphrases
- ms ms
- reduced graphene oxide
- molecularly imprinted
- solid phase extraction
- simultaneous determination
- liquid chromatography tandem mass spectrometry
- loop mediated isothermal amplification
- high performance liquid chromatography
- gold nanoparticles
- tandem mass spectrometry
- ultra high performance liquid chromatography
- prostate cancer
- drug induced
- gas chromatography mass spectrometry
- adverse drug
- label free
- real time pcr
- high resolution
- systematic review
- recombinant human
- emergency department
- wastewater treatment
- clinical practice
- gas chromatography
- electronic health record
- radical prostatectomy
- walled carbon nanotubes