Hands-On Times, Adherence to Recommendations and Variance in Execution among Three Different CPR Algorithms: A Prospective Randomized Single-Blind Simulator-Based Trial.
Sami RifaiTimur SellmannDietmar WetzchewaldHeidrun SchwagerFranziska TschanSebastian G RussoStephan C MarschPublished in: International journal of environmental research and public health (2020)
Compared to current ILCOR guidelines, two alternative CPR algorithms advocating cycles of uninterrupted chest compressions resulted in very similar hands-on times, fewer deviations from targets, and less within-team and between-team variance in execution.