A Simple Flow Injection Analysis-Tandem Mass Spectrometry Method to Reduce False Positives of C5-Acylcarnitines Due to Pivaloylcarnitine Using Reference Ions.
Takanari HattoriYoshitomo NotsuMisa TanakaMiki MatsuiTetsuo IidaJun WatanabeYoshimitsu OsawaSeiji YamaguchiShozo YanoTakeshi TaketaniHironori KobayashiPublished in: Children (Basel, Switzerland) (2022)
Flow injection analysis-tandem mass spectrometry (FIA-TMS) has been applied in a first-tier test of newborn screening (NBS). Although isovalerylcarnitine (i-C5), which is a diagnostic indicator of isovaleric acidemia (IVA), is isobaric with pivaloylcarnitine (p-C5), 2-methylbutyrylcarnitine, and n-valerylcarnitine, these isomers cannot be distinguished by the FIA-TMS. There are many reports of false positives derived from p-C5 due to the use of pivalate-conjugated antibiotics. In this study, we developed a new FIA-TMS method to distinguish i-C5 and p-C5. We found that the intensity ratio of product ions for i-C5 and p-C5 was different in a certain range even under the same analytical conditions. The product ions with the most distinct differences in ionic intensity between the isomers and the collision energies that produce them were determined to be m/z 246.2 > 187.1 and -15 V, respectively. In addition to the quantification ion, a reference ion was defined, and the similarity of the i-C5 and p-C5 reference ion ratios (i-C5 score and p-C5 score, respectively) were used to estimate which isomer (i-C5 and p-C5) was responsible for elevated C5 acylcarnitine in dried blood spots (DBSs). As a result of analyses of 11 DBS samples derived from pivalate-conjugated antibiotics and four DBS samples from IVA patients using our method, it was found that our method was able to correctly determine the type of C5-acylcarnitine (i-C5 or p-C5) in the DBS samples. Implementation of this new FIA-TMS method into the current NBS protocol will allow for a reduction in false positives in IVA.
Keyphrases
- tandem mass spectrometry
- ultra high performance liquid chromatography
- liquid chromatography
- high performance liquid chromatography
- transcranial magnetic stimulation
- simultaneous determination
- gas chromatography
- deep brain stimulation
- primary care
- high resolution
- randomized controlled trial
- end stage renal disease
- healthcare
- solid phase extraction
- ejection fraction
- newly diagnosed
- emergency department
- high frequency
- high resolution mass spectrometry
- ultrasound guided
- peritoneal dialysis
- prognostic factors
- ms ms
- data analysis
- drug induced