The accuracy of static computer-aided implant surgery: A systematic review and meta-analysis.

Ali TahmasebViviane WuDaniël WismeijerWim CouckeChristopher Evans
Published in: Clinical oral implants research (2019)
Different levels of quantity and quality of evidence were available for static computer-aided implant surgery (s-CAIS). Based on the present systematic review and its limitations, it can be concluded that the accuracy of static computer-aided implant surgery is within the clinically acceptable range in the majority of clinical situations. However, a safety marge of at least 2 mm should be respected. A lack of homogeneity was found in techniques adopted between the different authors and the general study designs.