Accuracy of new implant impression technique using dual arch tray and bite impression coping.
Shin-Eon LeeSung-Eun YangCheol-Won LeeWon-Sup LeeSu Young LeePublished in: The journal of advanced prosthodontics (2018)
Within limitations of this study, the accuracy of implant impression using a bite impression coping and dual arch tray is comparable to that of conventional pick-up impression.