High-power short duration and low-power long duration in atrial fibrillation ablation: A meta-analysis.
Jakrin KewcharoenChol TechorueangwiwatChanavuth KanitsoraphanThiratest LeesutipornchaiNazem AkoumThomas J BunchLeenhapong NavaravongPublished in: Journal of cardiovascular electrophysiology (2020)
When compared to the LPLD strategy, the HPSD strategy does not improve recurrent AT nor reduce periprocedural complication risks. However, subgroup analysis of the randomized controlled trial showed that HPSD significantly reduces AT recurrence. An HPSD strategy can significantly reduce total procedure and ablation times.