Drug-Coated Balloon vs Standard Percutaneous Transluminal Angioplasty for the Treatment of Atherosclerotic Lesions in the Superficial Femoral and Proximal Popliteal Arteries: One-Year Results of the MDT-2113 SFA Japan Randomized Trial.
Osamu IidaYoshimitsu SogaKazushi UrasawaShigeru SaitoMichael R JaffHong WangHiroko OokuboHiroyoshi Yokoinull nullPublished in: Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists (2017)
Results from the MDT-2113 SFA Japan trial showed superior treatment effect for DCB vs PTA, with excellent patency and low CD-TLR rates. These results are consistent with other IN.PACT SFA DCB trials and demonstrate the safety and effectiveness of this DCB for the treatment of femoropopliteal lesions in this Japanese cohort.