Login / Signup

Quantification of healthcare workers' exposure to cyclophosphamide, ifosfamide, methotrexate, and 5-fluorouracil by 24-h urine assay: A descriptive pilot study.

Marie PalaminiAnnick DufourRoxane TherrienJean-François DelisleGeneviève MercierSébastien GagnéNicolas CaronJean-François Bussières
Published in: Journal of oncology pharmacy practice : official publication of the International Society of Oncology Pharmacy Practitioners (2020)
No traces of cyclophosphamide, ifosfamide, methotrexate, or FBAL were found in the 24-h urine samples of 18 healthcare workers practicing in three healthcare facilities in Quebec. Although it was feasible to collect 24-h urine samples in this research project, it appears unrealistic to do so recurrently as part of a large-scale surveillance program.