Sensitive Detection of Exosomal Proteins via a Compact Surface Plasmon Resonance Biosensor for Cancer Diagnosis.
Chang LiuXie ZengZijian AnYunchen YangMaxwell EisenbaumXiaodong GuJosep M JornetGrace K DyMary E ReidQiaoqiang GanYun WuPublished in: ACS sensors (2018)
Exosomes are small extracellular vesicles released by cells for cell-cell communication. They play important roles in cancer development, metastasis, and drug resistance. Exosomal proteins have been demonstrated by many studies as promising biomarkers for cancer screening, diagnosis, and monitoring. Among many detection techniques, surface plasmon resonance (SPR) is a highly sensitive, label-free, and real-time optical detection method. Commercial prism-based wavelength/angular-modulated SPR sensors afford high sensitivity and resolution, but their large footprint and high cost limit their adaptability for clinical settings. Recently, a nanoplasmonic exosome (nPLEX) assay was developed to detect exosomal proteins for ovarian cancer diagnosis. However, comparing with conventional SPR biosensors, the broad applications of nanoplasmonic biosensors are limited by the difficult and expensive fabrication of nanostructures. We have developed an intensity-modulated, compact SPR biosensor (25 cm × 10 cm × 25 cm) which uses a conventional SPR sensing mechanism and does not require nanostructure fabrication. Calibration from glycerol showed that the compact SPR biosensor offered sensitivity of 9.258 × 103%/RIU and resolution of 8.311 × 10-6 RIU. We have demonstrated the feasibility of the compact SPR biosensor in lung cancer diagnosis using exosomal epidermal growth factor receptor (EGFR) and programmed death-ligand 1 (PD-L1) as biomarkers. It detected a higher level of exosomal EGFR from A549 nonsmall cell lung cancer (NSCLC) cells than BEAS-2B normal cells. With human serum samples, the compact SPR biosensor detected similar levels of exosomal EGFR in NSCLC patients and normal controls, and higher expression of exosomal PD-L1 in NSCLC patients than normal controls. The compact SPR biosensor showed higher detection sensitivity than ELISA and similar sensing accuracy as ELISA. It is a simple and user-friendly sensing platform, which may serve as an in vitro diagnostic test for cancer.
Keyphrases
- label free
- epidermal growth factor receptor
- sensitive detection
- small cell lung cancer
- low cost
- advanced non small cell lung cancer
- papillary thyroid
- induced apoptosis
- tyrosine kinase
- squamous cell
- end stage renal disease
- quantum dots
- loop mediated isothermal amplification
- single cell
- cell cycle arrest
- newly diagnosed
- ejection fraction
- prognostic factors
- peritoneal dialysis
- mesenchymal stem cells
- high throughput
- high resolution
- oxidative stress
- lymph node metastasis
- cell death
- brain metastases
- poor prognosis
- endoplasmic reticulum stress
- long non coding rna
- binding protein
- monoclonal antibody
- mass spectrometry