Effectiveness of soft coagulation in robot-assisted partial nephrectomy in preventing pseudoaneurysms and its influence on renal function based on propensity score-matched analysis.
Hayato HoshinaToru SugiharaAkira FujisakiHirotaka YokoyamaMasayuki KurokawaMasahiro YamazakiEi-Ichiro TakaokaSatoshi AndoTatsuya TakayamaHaruki KumeTetsuya FujimuraPublished in: Translational andrology and urology (2024)
The use of a soft coagulation system reduces pseudoaneurysm occurrence after partial nephrectomy. Although renal function decreased in the short-term for the use group, no long-term differences were observed.