Evaluation of a standardized protocol for thrombin generation using the calibrated automated thrombogram: A Nordic study.

Marcus LjungkvistKarin StrandbergErik BerntorpRoza ChairetiPål André HolmeOle Halfdan LarsenRiitta LassilaAnnukka JouppilaTimea SzantoEva M K Zetterberg
Published in: Haemophilia : the official journal of the World Federation of Hemophilia (2019)
With our standardization concept, we were able to produce TGA-CAT results as robust as standard coagulation assays used in the routine laboratories. Normalization with HemosIL RP may be considered in populations with low or unknown coagulability, while when analysing plasma samples from populations where hypercoagulability is known or suspected, normalization with Affinity RP may be preferred.