Login / Signup

Effect of the screw tightening sequence on the stress distribution of a dynamic compression plate: A pilot finite element study.

Xiaoreng FengWeichen QiChengyong WangFrankie LeungBin Chen
Published in: Journal of orthopaedic surgery (Hong Kong) (2020)
Using different screw tightening sequences to fix the same DCP can produce the same stability, which means in terms of fixation stability, after the two screws nearest to the fracture line are tightened, surgeons do not need to hesitate about the order in which the rest screws should be inserted during the surgery.
Keyphrases