Diagnostic Accuracy of Early Systolic Notching in Pulmonary Embolism.

Mehmet Ali AslanerFunda Karbek AkarcaŞakir Hakan AksuMerve YazlaÖzge CanGorkem KusAli ÇelikSelçuk ÖzkanSüleyman İbzeAdnan YamanogluMümin Murat YazıcıAslıhan Yürüktümen ÜnalAhmet Demircan
Published in: Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine (2021)
The pulmonary Doppler flow of ESN was moderate to high specific but low sensitive for PE in all ED patients. In the subgroup analysis, this finding was moderate specific and low sensitive.