Detecting of the Longitudinal Grouting Quality in Prestressed Curved Tendon Duct Using Piezoceramic Transducers.
Tianyong JiangBin HeYaowen ZhangLei WangPublished in: Sensors (Basel, Switzerland) (2020)
To understand the characteristics of longitudinal grouting quality, this paper developed a stress wave-based active sensing method using piezoceramic transducers to detect longitudinal grouting quality of the prestressed curved tendon ducts. There were four lead zirconate titanate (PZT) transducers installed in the same longitudinal plane. One of them, mounted on the bottom of the curved tendon duct, was called as an actuator for generating stress waves. The other three, pasted on the top of the curved tendon duct, were called as sensors for detecting the wave responses. The experimental process was divided into five states during the grouting, which included 0%, 50%, 75%, 90%, and 100% grouting. The voltage signals, power spectral density (PSD) energy and wavelet packet energy were adopted in this research. Experimental results showed that all the amplitudes of the above analysis indicators were small before the grouting reached 90%. Only when the grouting degree reached the 100% grouting, these parameters increased significantly. The results of different longitudinal PZT sensors were mainly determined by the distance from the generator, the position of grouting holes, and the fluidity of grouting materials. These results showed the longitudinal grouting quality can be effectively evaluated by analyzing the difference between the signals received by the PZT transducers in the curved tendon duct. The devised method has certain application value in detecting the longitudinal grouting quality of prestressed curved tendon duct.