Real-time surveillance of left atrial appendage thrombus during contrast computed tomography imaging for catheter ablation: THe Reliability of cOMputed tomography Beyond UltraSound in THROMBUS detection (THROMBUS) study.
Tetsuma KawajiHitomi NumamotoShintaro YamagamiRyu MabuchiTakaaki KitamuraNaomi EnokiKoji KoizumiShotaro KanaoMasashi KatoTakafumi YokomatsuSatoshi ShizutaShinji MikiKoh OnoKaori TogashiTakeshi KimuraPublished in: Journal of thrombosis and thrombolysis (2019)
Left atrial contrast computed tomography (LA-CT) as well as transesophageal echocardiography (TEE) can exclude left atrial appendage (LAA) thrombus, but is sometimes unable to evaluate LAA due to incomplete LAA filling. The aim of the current study was to validate the utility of real-time approach of LA-CT with real-time surveillance of LAA-filling defect (FD). We enrolled consecutive 894 patients with LA-CT studies acquired for catheter ablation and compared the diagnostic accuracy in demonstrating LAA-FD between conventional protocol (N = 474) and novel protocol with real-time surveillance of LAA-FD immediately after the initial scanning and, when necessary, adding delayed scanning in the supine or prone position (N = 420). Primary endpoint was severity of LAA-FD classified into the 3 groups: "Grade-0" for complete filling of contrast, "Grade-1" for incomplete filling of contrast, and "Grade-2" for complete FD of contrast. The prevalence of Grade-1 and Grade-2 FD was 17.3% and 11.2% in conventional protocol, whereas there was no patient with Grade-2 FD, and only 1 patient with Grade-1 FD after the additional scanning in novel protocol. In 5 patients with suspected LAA thrombus both by TEE and Grade-2 FD in LA-CT by the conventional protocol, ablation procedure was canceled due to diagnosis of LAA thrombus. Conversely, 4 patients with suspected LAA thrombus by TEE in novel protocol group was proved to have intact LAA by LA-CT with and without additional scanning. This novel approach with real-time surveillance improved the diagnostic accuracy of LA-CT in detecting LAA-FD, suggesting potential superiority of LA-CT over TEE in excluding LAA thrombus.
Keyphrases
- computed tomography
- contrast enhanced
- left atrial appendage
- catheter ablation
- dual energy
- atrial fibrillation
- image quality
- left atrial
- positron emission tomography
- magnetic resonance imaging
- magnetic resonance
- randomized controlled trial
- high resolution
- public health
- electron microscopy
- case report
- mitral valve
- risk factors
- heart failure
- minimally invasive
- mass spectrometry