Does the choice of syndesmotic screw versus suture button in ankle surgery has a silver lining? - a technical note.
Pieter D'HoogheMotasem SalamehPublished in: Journal of experimental orthopaedics (2020)
The presented technique of sequential dynamic and static fixation of associated syndesmotic injuries combined advantages of both syndesmotic screws and suture button implants. In an aim to allow earlier return to play in an elite football player. This opens the way for higher level of evidence clinical trials.