Association of endoscopist colonoscopy quality measures with follow-up colonoscopy outcomes after positive stool tests (mt-sDNA or FIT): Retrospective cross-sectional analysis of data from the New Hampshire Colonoscopy Registry.
Lynn F ButterlyWilliam M HiseyChristina M RobinsonBonny L KneedlerJoseph C AndersonPublished in: The American journal of gastroenterology (2024)
The frequency of negative colonoscopies after positive stool tests was significantly higher in exams performed by endoscopists with low ADR and CSSDR. Our results also suggest a benchmark target of at least 40% for ADR in patients with mt-sDNA+ or FIT+ tests, and 20% for SSLs in mt-sDNA+ patients.