A pilot randomized controlled trial of EKG for neonatal resuscitation.
Anup KatheriaKathy ArnellMelissa BrownKasim HassenMauricio MaldonadoWade RichNeil FinerPublished in: PloS one (2017)
EKG provides an earlier, and more accurate heart rate than pulse rate from an oximeter during stabilization of preterm infants, allowing earlier intervention. All interventions were started earlier in the unblinded EKG group but these numbers were not significant in this small trial. Earlier EKG placement before pulse oximeter placement may affect other interventions, but this needs further study.