What Is the Smallest Change in Pulse Wave Velocity Measurements That Can Be Attributed to Clinical Changes in Arterial Stiffness with Certainty: A Randomized Cross-Over Study.

Mario PodrugBorna ŠunjićPjero KorenVarja ĐogašIvana MudnićMladen BobanAna Jeroncic
Published in: Journal of cardiovascular development and disease (2023)
Pulse wave velocity (PWV), a direct measure of arterial stiffness, is a promising biomarker of cardiovascular risk and a cardiovascular surrogate outcome. The resolution for detecting its smallest clinically significant change is dependent on the expected reproducibility, but there is currently no consensus on this. We estimated the PWV reproducibility in a range of intra-subject values that were observed over a 2 week period in a broad range of participants and under clinically relevant experimental conditions (two observers, morning/afternoon sessions, and number of visits) using SphygmoCor and Arteriograph devices. Each participant was recorded 12 times with each device over three visits, one week apart, and two morning and two afternoon recordings were taken per visit. The factors affecting reproducibility and the discrepancies between the consecutive PWV measurements for each device were also examined using multilevel mixed-effect models. We show that current PWV estimation guidance recommending 2 + 1 measurements is suboptimal because the PWV range was outside of the 1 m/s threshold for most of the participants, which is proposed as a minimal clinically important difference. The best reproducibility was yielded with median of four measurements and a 1.1 m/s threshold. Although PWV reproducibility and repeatability are frequently used interchangeably in studies, we demonstrated that despite their relative measures of variability (e.g., coefficient of variation) being comparable, their ranges revealed a clinically significant difference between them. We also found that different physiological variables were predictors of the discrepancy between the consecutive measurements made by the two devices, which is likely due to their distinct modes of operation. The evidence base for PWV reproducibility is limited, and more research is needed to deepen our understanding of the variation in arterial stiffness over time, as well as fluctuations within a population group and in an intervention setting.
Keyphrases
  • blood pressure
  • randomized controlled trial
  • blood flow
  • computed tomography
  • single cell
  • clinical practice
  • magnetic resonance
  • placebo controlled
  • study protocol
  • double blind