Symmetric CTA Collaterals Identify Patients with Slow-progressing Stroke Likely to Benefit from Late Thrombectomy.
Robert William RegenhardtRamon Gilberto GonzálezJulian HeMichael H LevAneesh Bhim SinghalPublished in: Radiology (2021)
Background Understanding ischemic core growth rate (IGR) is key in identifying patients with slow-progressing large vessel occlusion (LVO) stroke who may benefit from delayed endovascular thrombectomy (EVT). Purpose To evaluate whether symmetric collateral pattern at CT angiography (CTA) can help to identify patients with low IGR and small 24-hour diffusion-weighted MRI ischemic core volume in patients with LVO not treated with reperfusion therapies. Materials and Methods In this secondary analysis of clinical trial data from before EVT became standard of care from January 2007 to June 2009, patients with anterior proximal LVO not treated with reperfusion therapies were evaluated. All patients underwent admission CTA and at least three MRI examinations at four time points over 48 hours. Arterial phase CTA collaterals at presentation were categorized as symmetric, malignant, or other. Diffusion-weighted MRI ischemic core volume and IGR at multiple time points were determined. The IGR at presentation was defined as follows: (ischemic core volume in cubic centimeters)/(time since stroke symptom onset in hours). Multivariable analyses and receiver operator characteristic analyses were used. Results This study evaluated 31 patients (median age, 71 years; interquartile range, 61-81 years; 19 men) with median National Institutes of Health Stroke Scale (NIHSS) score of 13. Collaterals were symmetric (45%; 14 of 31), malignant (13%; four of 31), or other (42%; 13 of 31). Median ischemic core volume was different between collateral patterns at all time points. Presentation was as follows: symmetric, 16 cm3; other, 69 cm3; and malignant, 104 cm3 (P < .001). At 24 hours, median ischemic core volumes were as follows: symmetric, 28 cm3; other, 156 cm3; and malignant, 176 cm3 (P < .001). Median IGR was also different, and most pronounced at presentation: symmetric, 4 cm3 per hour; other, 17 cm3 per hour; and malignant, 20 cm3 per hour (P < .001). After multivariable adjustment, independent determinants of higher presentation IGR included only higher NIHSS (parameter estimate [β = 0.20; 95% CI: 0.05, 0.36; P = .008) and worse collaterals (β = -2.90; 95% CI: -4.31, -1.50; P < .001). The only independent determinant of 24-hour IGR was worse collaterals (β = -2.03; 95% CI: -3.28, -0.78; P = .001). Symmetric collaterals had sensitivity of 87% (13 of 15) and specificity of 94% (15 of 16) for 24-hour ischemic core volume less than 50 cm3 (area under the receiver operating characteristic curve, 0.92; 95% CI: 0.81, 1.00; P < .001). Conclusion In patients with large vessel occlusion not treated with reperfusion therapies, symmetric collateral pattern at CT angiography was common and highly specific for low ischemic core growth rate and small 24-hour ischemic core volume as assessed at diffusion-weighted MRI. After further outcome studies, collateral status at presentation may prove useful in triage for endovascular thrombectomy, especially when MRI and CT perfusion are unavailable. Clinical trial registration no. NCT00414726. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Messina in this issue.
Keyphrases
- contrast enhanced
- diffusion weighted
- cerebral ischemia
- magnetic resonance imaging
- blood pressure
- magnetic resonance
- computed tomography
- clinical trial
- ischemia reperfusion injury
- subarachnoid hemorrhage
- end stage renal disease
- diffusion weighted imaging
- acute ischemic stroke
- brain injury
- atrial fibrillation
- newly diagnosed
- blood brain barrier
- healthcare
- chronic kidney disease
- emergency department
- randomized controlled trial
- case report
- public health
- mental health
- acute coronary syndrome
- machine learning
- peritoneal dialysis
- study protocol
- deep learning
- structural basis
- left ventricular
- pain management
- dual energy