Measurement of heating coil temperature for e-cigarettes with a "top-coil" clearomizer.

Wenhao ChenPing WangKazuhide ItoJeff FowlesDennis ShustermanPeter A JaquesKazukiyo Kumagai
Published in: PloS one (2018)
This study established a simple and straight-forward protocol to systematically measure e-cigarette coil heating temperature under dry, wet-through-wick, and full-wet conditions. In addition to applied power, the composition of e-liquid, and the devices' ability to efficiently deliver e-liquid to the heating coil are important product design factors effecting coil operating temperature. Precautionary temperature checks on e-cigarettes under manufacturer-recommended normal use conditions may help to reduce the health risks from exposure to toxic carbonyl emissions associated with coil overheating.