Login / Signup

Can a Total Knee System Providing 1 mm Increment of Polyethylene Insert Thickness Offer a Clinical Benefit?

Dhong-Won LeeHyuk-Jin JangMan Soo KimKeun-Young ChoiSung-An HongYong In
Published in: Medicina (Kaunas, Lithuania) (2024)
Background and Objectives : The purpose of this study was to compare clinical outcomes and polyethylene (PE) insert thickness between total knee arthroplasty (TKA) systems providing 1 mm and 2 mm increments. Materials and Methods : In this randomized controlled trial, 50 patients (100 knees) undergoing same-day or staggered bilateral TKA were randomized to receive a TKA system providing 1 mm increments in one knee (1 mm group) and a TKA system providing 2 mm increments in the other knee (2 mm group). At 2 years postoperatively, Knee Society Score (KSS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score, Forgotten Joint Score (FJS), range of motion (ROM), and insert thicknesses were compared between the groups. Results : A total of 47 patients (94 knees) participated in follow-up analysis. In each group, patient-reported outcomes improved significantly after TKA (all, p < 0.05). There were no significant differences in patient-reported outcomes. The mean ROM was not significantly different between groups at preoperative and 2-year points. The rate of postoperative flexion contracture ≥ 5° was 2.1% and 4.3%, and the rate of postoperative recurvatum ≥ 5° was 4.3% and 2.1% in the 1 mm group and 2 mm, respectively (all, p = 1.000). Mean insert thickness was significantly thinner in the 1 mm group than the 2 mm group ( p = 0.001). The usage rate of a thick insert (≥14 mm) was 12.7% and 38.3% in the 1 mm group and 2 mm group ( p = 0.005). Conclusions : The use of a TKA system providing 1 mm PE insert thickness increments offered no clinical benefit in terms of patient reported outcomes over systems with 2 mm increments at 2 years of follow-up. However, the TKA system with 1 mm increments showed significantly thinner PE insert usage. As a theoretical advantage of 1 mm increments has yet to be proven, the mid- to long-term effects of thinner PE insert usage must be determined.
Keyphrases