Use of a two-sided tolerance interval in the design and evaluation of biosimilarity in clinical studies.
Chieh ChiangChi-Tian ChenChin-Fu HsiaoPublished in: Pharmaceutical statistics (2020)
In assessing biosimilarity between two products, the question to ask is always "How similar is similar?" Traditionally, the equivalence of the means between products is the primary consideration in a clinical trial. This study suggests an alternative assessment for testing a certain percentage of the population of differences lying within a prespecified interval. In doing so, the accuracy and precision are assessed simultaneously by judging whether a two-sided tolerance interval falls within a prespecified acceptance range. We further derive an asymptotic distribution of the tolerance limits to determine the sample size for achieving a targeted level of power. Our numerical study shows that the proposed two-sided tolerance interval test controls the type I error rate and provides sufficient power. A real example is presented to illustrate our proposed approach.