Nonsteroidal anti-inflammatory drug monitoring in serum: a Tb-MOF-based luminescent mixed matrix membrane detector with high sensitivity and reliability.
Xiao LianLele ChengJingrui ShanMingzai WuFangcai ZhengHeling NiuPublished in: Dalton transactions (Cambridge, England : 2003) (2023)
The identification of drugs or biomolecules for public health monitoring requires facile analytical technologies with excellent sensitivity, portability and reliability. In the past decades, different sensing materials have inspired the development of various bioanalytical strategies. However, sensing platforms based on powder materials are not suitable for medical diagnosis, which limits further exploration and application of biosensors. Herein, a point-of-care testing (POCT) membrane was designed from an energy competition mechanism and achieved the detection of the nonsteroidal antiphlogistic diclofenac, and exhibited remarkable testing efficacy at the ppb level. The mixed matrix membrane (MMM) sensor consists of electrospun polyacrylonitrile nanofibers and luminescent Tb-MOFs and possess the advantages of high stability, outstanding anti-interference ability, efficient detection (LOD = 98.5 ppb) and easy visual recognition. Furthermore, this MMM sensor exhibits excellent recyclability in serum, which is beneficial for developing a portable and convenient device to distinguish diclofenac in practical sensing applications. Meanwhile, the feasibility and mechanism of this recyclable sensor were verified by theory and experiments, indicating that it is a promising device for diclofenac detection in biological environments to evaluate the toxic effect caused by the accumulation of nonsteroidal drugs.