Retention of titanium copings to implant-supported fixed dental prostheses.

Sieu Yien ChiamHsin Lin LeeArmand E BedrossianQianhui XuWilliam KuykendallAnna RenTimothy M HessVan RamosKwok-Hung Chung
Published in: Journal of prosthodontics : official journal of the American College of Prosthodontists (2023)
When bonding IFDPs onto titanium copings, quick-set resin provided significantly higher retention force for prepolymerized denture acrylic resin prostheses. Conical and cylindrical titanium copings performed similarly when cemented to Zirconia with Panavia SA cement under the same protocol. The stability of the bonded interface and retention forces between zirconia prostheses and titanium copings varied from the cement used. This article is protected by copyright. All rights reserved.