Refinement of the Hounsfield look-up table by retrospective application of patient-specific direct proton stopping-power prediction from dual-energy CT.
Patrick WohlfahrtChristian MöhlerWolfgang EnghardtMechthild KrauseDaniela KunathStefan MenkelEsther G C TroostSteffen GreilichChristian RichterPublished in: Medical physics (2020)
The incorporation of patient-specific correlations between CT number and SPR, derived from a retrospective application of DirectSPR to a broad patient cohort, improves the SPR accuracy of the current state-of-the-art HLUT approach. The DirectSPR-based adapted HLUT has been clinically implemented at the University Proton Therapy Dresden (Dresden, Germany) in 2017. This already facilitates the benefits of an improved DECT-based tissue differentiation within clinical routine without changing the general approach for range prediction (HLUT), and represents a further step toward full integration of the DECT-based DirectSPR method for treatment planning in proton therapy.