Effects of Vibration on Accelerating Orthodontic Tooth Movement in Clinical and In Vivo Studies: A Systematic Review.
Selma PascoalSofia OliveiraMargaux AscioneJorge PereiraÓscar CarvalhoTeresa PinhoPublished in: Dentistry journal (2024)
This systematic review aims to assess the impact of high (>30 Hz) and low (≤30 Hz) frequency vibrations on orthodontic tooth movement (OTM). Several articles were collected through a systematic search in the databases MEDLINE and SCOPUS, following PRISMA methodology and using a PICO question. Relevant information on selected articles was extracted, and the quality of each study was assessed by the quality assessment tools EPHPP, ROBINS-1 and STAIR. Out of 350 articles, 30 were chosen. Low-frequency vibrations did not seem to accelerate OTM with aligners or fixed appliances, despite some positive outcomes in certain studies. Conversely, high-frequency vibrations were linked to increased aligner change, tooth movement, and space closure with fixed appliances. In vivo studies reported favourable results with high-frequency vibrations (60 Hz to 120 Hz), which stimulate bone biomarkers, facilitating alveolar bone remodelling. The results suggest that high-frequency vibration effectively speeds up orthodontic tooth movement, showing promise in both in vivo and clinical studies. Larger-scale research is needed to strengthen its potential in orthodontics.
Keyphrases