Lower intra-abdominal pressure has no cardiopulmonary benefits during laparoscopic colorectal surgery: a double-blind, randomized controlled trial.
Youn Joung ChoHyesun PaikSeung-Yong JeongJi Won ParkWoo Young JoYunseok JeonKook Hyun LeeJeoung-Hwa SeoPublished in: Surgical endoscopy (2018)
We observed few cardiopulmonary benefits but poor surgical conditions in the low intra-abdominal pressure during laparoscopy. Considering cardiopulmonary dynamics and surgical conditions, the standard intra-abdominal pressure may be preferable to the low pressure for laparoscopic surgery.