Login / Signup

A protocol for automated a posteriori adaptive meshing with SimVascular: a test case.

Akash GuptaEthan Kung
Published in: BMC research notes (2020)
In all three trials, an overall reduction in mesh error metrics is observed (range 47%-86%). The increase in the number of elements through each adaptation never exceeded the mesh size of the pre-adaptation mesh by one order of magnitude. In all three trials, the protocol resulted in consistent, repeatable improvements in mesh error metrics, no losses of geometric fidelity and steady increments in the number of elements in the mesh. Our proposed protocol prevented the aforementioned undesirable outcomes and can potentially save new users considerable effort and computing resources.
Keyphrases
  • randomized controlled trial
  • metabolic syndrome
  • high throughput
  • insulin resistance
  • single cell