Login / Signup

Environmental Impact of Flexible Cystoscopy: A Comparative Analysis Between Carbon Footprint of Isiris ® Single-Use Cystoscope and Reusable Flexible Cystoscope and a Systematic Review of Literature.

Victoria JahrreissPierre SarrotNiall F DavisBhaskar Kumar Somani
Published in: Journal of endourology (2024)
Introduction: There is an absence of data on the environmental impact of single-use flexible cystoscopes. We wanted to review the existing literature about carbon footprint of flexible cystoscopy and analyze the environmental impact of the Isiris ® (Coloplast © ) single-use flexible cystoscope compared to reusable flexible cystoscopes. Methods: First, a systematic review on single-use and reusable cystoscope carbon footprint was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement. Second, carbon footprints of Isiris single-use flexible cystoscope and reusable cystoscope were analyzed and compared. Life cycle of the single-use flexible cystoscope was divided in three steps: manufacturing, sterilization, and disposal. For the reusable cystoscope, several steps were considered to estimate the carbon footprint over the life cycle: manufacturing, washing/sterilization, repackaging, repair, and disposal. For each step, the carbon footprint values were collected and adapted from previous comparable published data on flexible ureteroscope. Results: The systematic literature review evidenced total carbon emissions within a range of 2.06 to 2.41 kg carbon dioxide (CO 2 ) per each use of single-use flexible cystoscope compared to a wide range of 0.53 to 4.23 kg CO 2 per each case of reusable flexible cystoscope. The carbon footprint comparative analysis between Isiris single-use flexible cystoscope and reusable cystoscope concluded in favor of the single-use cystoscope. Based on our calculation, the total carbon emissions for a reusable flexible cystoscope could be refined to an estimated range of 2.40 to 3.99 kg CO 2 per case, depending on the endoscopic activity of the unit, and to 1.76 kg CO 2 per case for Isiris single-use cystoscope. Conclusion: The results and our systematic literature review demonstrated disparate results depending on the calculation method used for carbon footprint analysis. However, the results tend rather toward a lower environmental impact of single-use devices. In comparison to a reusable flexible cystoscope, Isiris compared favorably in terms of carbon footprint.
Keyphrases
  • life cycle
  • systematic review
  • randomized controlled trial
  • carbon dioxide
  • risk assessment
  • human health
  • big data
  • ultrasound guided
  • artificial intelligence