Piezoelectric MEMS Acoustic Transducer with Electrically-Tunable Resonant Frequency.
Alessandro NastroMarco FerrariLibor RuferSkandar BasrourVittorio FerrariPublished in: Micromachines (2022)
The paper presents a technique to obtain an electrically-tunable matching between the series and parallel resonant frequencies of a piezoelectric MEMS acoustic transducer to increase the effectiveness of acoustic emission/detection in voltage-mode driving and sensing. The piezoelectric MEMS transducer has been fabricated using the PiezoMUMPs technology, and it operates in a plate flexural mode exploiting a 6 mm × 6 mm doped silicon diaphragm with an aluminum nitride (AlN) piezoelectric layer deposited on top. The piezoelectric layer can be actuated by means of electrodes placed at the edges of the diaphragm above the AlN film. By applying an adjustable bias voltage V b between two properly-connected electrodes and the doped silicon, the d31 mode in the AlN film has been exploited to electrically induce a planar static compressive or tensile stress in the diaphragm, depending on the sign of V b , thus shifting its resonant frequency. The working principle has been first validated through an eigenfrequency analysis with an electrically induced prestress by means of 3D finite element modelling in COMSOL Multiphysics ® . The first flexural mode of the unstressed diaphragm results at around 5.1 kHz. Then, the piezoelectric MEMS transducer has been experimentally tested in both receiver and transmitter modes. Experimental results have shown that the resonance can be electrically tuned in the range V b = ±8 V with estimated tuning sensitivities of 8.7 ± 0.5 Hz/V and 7.8 ± 0.9 Hz/V in transmitter and receiver modes, respectively. A matching of the series and parallel resonant frequencies has been experimentally demonstrated in voltage-mode driving and sensing by applying V b = 0 in transmission and V b = -1.9 V in receiving, respectively, thereby obtaining the optimal acoustic emission and detection effectiveness at the same operating frequency.
Keyphrases
- energy transfer
- quantum dots
- mechanical ventilation
- reduced graphene oxide
- randomized controlled trial
- systematic review
- finite element
- loop mediated isothermal amplification
- intensive care unit
- highly efficient
- high frequency
- oxidative stress
- visible light
- gold nanoparticles
- solid state
- label free
- high glucose
- sensitive detection
- endothelial cells
- ionic liquid
- data analysis
- light emitting