Login / Signup

Time-of-Flight PET/CT Imaging of Ga-68-Dotatate: Normal Pattern, SUV Quantification, and Differences from Non-Time-of-Flight Imaging.

Matthew Clifton MillerAvani T BansalDaniel WingardMaria Liza LindenbergDerek J StockerStephen AdlerKalpna Prasad
Published in: World journal of nuclear medicine (2024)
Purpose  The biodistribution of gallium-68-dotatate (Ga-68-dotatate) and standardized uptake values (SUVs) using non-time-of-flight (TOF) positron emission tomography/computed tomography (PET/CT) cameras is well established. However, with the eventual retirement of older PET cameras and their replacement with newer, highly sensitive TOF PET/CT cameras, where SUV max measurements are reportedly higher, updated knowledge of normal SUV max range is needed and, to our knowledge, not previously reported. Our objectives are as follows: To establish normal Ga-68-dotatate TOF SUV max database for common structures and to aid the visual detection of abnormalities objectively. To compare SUV max values using the TOF and non-TOF algorithms. Methods  Fifty consecutive patients referred routinely to our nuclear medicine service (20 men, 30 women; median age 55 years) with presumed neuroendocrine tumors underwent Ga-68-dotatate scans on a PET-CT camera having capability of reconstructing both TOF/non-TOF images. Region of interests (ROIs) were drawn around 24 normal structures as well as the primary lesion with abnormal radiotracer uptake and SUV max was measured. The same ROI was analyzed using both algorithms simultaneously and both TOF and non-TOF SUV max values were compared. Results  Twelve hundred ROIs were evaluated. Non-TOF Ga-68-dotatate uptake in normal structures was in alignment with previously published studies. As compared to non-TOF, TOF images had better target to background ratios visually. TOF SUV max was higher for all structures except for lung and brain. TOF SUV max was more than double in adrenals/uncinate process of the pancreas; approximately 1.8 times in abnormal lesions, lymph nodes, pineal gland; and greater than 1.5 times in thyroid, breast, and pancreatic head. Conclusion  Normal database of Ga-68-dotatate TOF SUV max is provided for common structures to aid visual detection of abnormalities objectively. Overall, TOF SUV max measures higher in identical ROIs, with abnormal lesions measuring approximately 1.8 times higher versus non-TOF technology. These findings need to be taken in consideration when comparing patient scans imaged on different PET/CT technologies.
Keyphrases