Optimised versus standard automated peritoneal dialysis regimens pilot study (OptiStAR): A randomised controlled crossover trial.
Karin BerglingJavier de ArteagaFabián LedesmaCarl Mikael ÖbergPublished in: Peritoneal dialysis international : journal of the International Society for Peritoneal Dialysis (2022)
Optimised treatments were feasible and well tolerated in this small pilot study. Despite no difference in absorbed glucose, results indicate possible improvements of ultrafiltration efficiency and small solute clearances by optimised regimens. Use of optimised prescriptions as glucose sparing strategy should be evaluated in larger study populations.