Login / Signup

Relationship between low tube voltage (70 kV) and the iodine delivery rate (IDR) in CT angiography: An experimental in-vivo study.

Michael M LellUlrike FleischmannHubertus PietschJohannes G KorporaalUlrike HaberlandAndreas H MahnkenThomas G FlohrMichael UderGregor Jost
Published in: PloS one (2017)
All protocols provided sufficient arterial enhancement. The use of a 70 kV CTA protocol is recommended because of a 50% reduction of total CM volume and a 50% reduced flow rate while maintaining the bolus profile. In contrast to pulmonary arterial enhancement, the systemic arterial enhancement improved only slightly increasing the IDR from 1.5 g/s to 3 g/s because of bolus dispersion of the very short bolus (3s) in the lungs.
Keyphrases
  • dual energy
  • randomized controlled trial
  • pulmonary hypertension
  • magnetic resonance
  • image quality
  • magnetic resonance imaging
  • contrast enhanced